Sample Size: 8 or 12 Well Microwell Strips (Single or Double). Applications: Absorbance, Concentration Curve, Single-point Concentration, Qualitative (Cutoff) Test. Photometric Methods: Monochromatic & Bichromatic, within the wavelength range of 400nm to 700nm. Absorbance Range: -1.000 to +3.000 Optical Density (OD) indication, 0 to +3.000 OD measurement. Indicated Range: >3.000 OD for informational purposes only. Precision (Standard Calibration): Monochromatic, neutral density samples: ± 1.25% Coefficient of Variation (CV) or ± 0.003 OD (whichever is greater) from 0 to 2.000 OD. ±3% CV from 2.000 OD to 3.000 OD. Bichromatic, colored samples: ± 2% CV or ± 0.006 OD (whichever is greater) from 0 to 1.350 OD. ±3.5% CV from 1.350 OD to 1.800 OD. Resolution: 0.001 OD Detector: Silicon Photodiode. |
|
Light Source: Long-life Tungsten Lamp; Average life of 20,000 hours. Wavelength Range: 400nm to 700nm. Filter Capacity: 6-position Filter Wheel, with 6-interference standard filters: 405nm, 450nm, 490nm, 540nm, 630nm and 650nm. (Other wavelengths, from 400nm to 700nm, are available by special order.) Removable Software Cartridge: Stores up to 20 custom immunoassay protocols. Open programming format. Display: 2 x 24 Character Alphanumeric LCD. Printer (Built-in): 40 Column Alphanumeric and Graphic Printer. Dimensions: 3 9/16" (9.04 cm) High, 10 1/4" (26.03 cm) Wide, 11.0" (27.94 cm) Deep. Weight: 4Lbs (1.80 Kg).
|
Interface Port: RS-232 Serial Port; allows sample data to be exported to a PC computer; PC Interface Software optional. MicroReader 3 Accessories &
Options
Single Well Adapter (#2027-125): Allows individual wells, from 1 to 8, to be run using BREAK-AWAY microwell strips. NUNC Microwell Strip Adapter (#2027-126): Allows the use of this type of microwell strip with the MicroReader 3. MicroReader 3 Test Fixture Set (#2027-128): Allows one to confirm the MicroReader 3 is operating within its specifications. |
Additional Software Packages (Order by Name): Coagulation Software: Measures the delta-absorbance between a given substance and a standard well and converts the delta-absorbance value to concentration using a preprogrammed curve. Delta-Absorbance (Non-Kinetic) Software: MicroReader 3 groups a standard and a sample into a pair so that the absorbance readings can be subtracted in order to determine the "difference" between them. Auto-Logit Test Software: Similar to a Concentration Curve Test, its X-Axis is based concentration. However, the Y-Axis is always based on Logit of absorbance, rather than "absorbance only". Microplate Washer
Option
|
Hyperion, Inc., 14100 S.W. 136th Street, Miami, Florida 33186 Copyright © 1997 - 2002, Hyperion Inc. |